Repairs
We provide quick repair turnaround time and warranty our workmanship.
Nationwide Supply
Nationwide supply of durable, new and professionally refurbished equipment.
Servicing & Maintenance
We are proficient with medical electronics PCB Repairs, servicing & Maintenance.
AMC Contract
we are undertaking the repair and maintenance job most all the medical equipment.
The new Vivo life-support ventilator combines high quality technology, robustness and premium design to treat all patients in any environment in the best way. The treatment can be personalized to the patient’s needs with almost all Volume and Pressure modes desired in a ventilator. It also includes our patent-pending eSync technology and a full range of settings, including target volume which gives you unique flexibility. Maximal flexibility of operation by the multiple types of circuit for both invasive and non-invasive ventilation.
Specifications:
• Patient Modes:Adult, Paediatric (>10 kg)
• Device Modes: Clinical, Home
• IPAP/EPAP: 4 to 40 cmH2O / 2 to 20 cmH2O or IPAP -2 cmH2O
• CPAP: 4 to 20 cmH2O
• Breath Rate: 4 to 40 BPM
• Inspiratory Time: 0.3 to 5 s
• Rise Time: 1 to 9
• Inspiratory Trigger (eSync): 1 to 9, Off
• Expiratory Trigger: 1 to 9
• Target Volume: 200-1500 ml
• Ramp function setting: 10 to 60 min, Off (PCV, PSV and CPAP mode)
• Humidification setting: 1 to 9 (10 to 30 mgH2O/L)
• Audible alarm setting: 1 to 9
• Maximum flow:> 200 litres/min
• Minimal Inspiratory Time Off: 0.3 to 3.0 s
• Maximal Inspiratory Time: 0.3 to 3.0 s, Off. (0.3 to in Paediatric Mode)
• Noise level (at 10 cmH2O constant pressure): Less than 30 dB(A)
• Indications: Pressure; bar graph and digital data: 0 to 40 cmH2O
• Calculated tidal volume accuracy: ± 20% or ± 20 ml (whichever is the greatest)
• Leakage calculation accuracy: ± 20%
• Total Breath Rate: 0 to 60 BPM (Breaths Per Minute)
• I/E Ratio: 1 :10 to 10 :1
• Alarms
Audible Alarm Level: 35 to 85 dB(A)
• Low pressure alarm, high pressure alarm, low volume alarm, low breath rate alarm, high breath rate alarm, low leakage alarm, high leakage alarm, low internal battery warning, low power alarm, internal function failure alarms.
Power Supplies
• Mains supply: 100 to 240 V AC
• Internal battery / External battery: Capacity 3.8 Ah / 12/24 V DC
Operating Conditions
• Recommended mask leakage: 20 to 40 litres/min at 10 cmH2O
• Minimum mask leakage: 12 litres/min at 4 cmH2O
Dimensions
• W x H x D: 190 x 243 x 223 mm (without HA20)
• Weight: 4.0 kg (without HA20)